2H FILLS FOR ODOR CONTROL AND AMMONIA REDUCTION

EXHAUST AIR CLEANING IN STABLES

Dust and ammonia are the substances to be cleaned from the waste air. Prescribed are cleaning efficiencies from 70-90% depending on where the sheds/stables are located. To efficiently and economically comply with this task, filling materials are needed which can be used in both counter and cross-flow applications (e.g. tunnel ventilation) in local waste air cleaning systems. The filling materials we have developed comply with all the requirements and have proved their operating efficiency in hundreds of installations.

  • HUMIPACKING® KFP 158

    HUMIPACKING® KFP 158 for exhaust air cleaning

  • Cross-Fluted Fill KFP 319

    Cross-Fluted Fill KFP 319

  • Vertical Flow Fill KVP 323

    Vertical Flow Fill KVP 323

  • Drift eliminator TEP 130

    Drift eliminator TEP 130 - chamber type

  • Drift eliminator TAP 160

    Drift eliminator TAP 160 - profile type

  • Trickle Grid Fill NET 38 150

    Trickle Grid Fill NET 38 150

We supply the ideal packing material for different plant requirements. Whether chemical exhaust air cleaning in cross-flow systems or biological exhaust air cleaning in counter-flow system, by co-operating with our customers, we are able to offer the most suitable packing material for any system concept.

Ask us. Our experts are at your side for any advice.

Technical Data

KFP 158
MaterialPP (Polypropylene)
Specific surface (m²/m³)~ 320
Max. height (mm)2.700
Max. width (mm)600
Depth (mm)150
ChannelsCross-fluted
HUMIPACKING is suited for cross-flow applications only.

General features of 2H fill media

PPPVC
Void ratio (%)< 97%
Length max (mm)2400 mm
Width max (mm)600 mm
Standard height (mm)300 or 600 mm
Continuous operation temperature (°C)70°C55°C
Max. operation temperature (short term) (°C)80°C60°C

Technical Data

KFP319
KFC319
KFP327
KFC327
KVP323
Specific surface [m2/m3]150125125
Void ratio (%)> 97> 97> 97
Corrugation height (mm)192745
ChannelsCross-flutedCross-flutedVertical flow

Technical Data

KFC, KVC fills are made of PVC
KFP, KVP fills are made of PP (Polypropylene)

NET38 150
MaterialPP (Polypropylene)
Effective surface (m²/m³)150
Void ratio (%)> 97
Corrugation height (mm)20
Length (mm)908
Width (mm)604
Height (mm)450

Technical Data

TEP 130TEC 130TAP 160 with Spacer TAS 033
MaterialPPPVCPP
Max. length / width (mm)2400 / 7002400 / 8006000 / 330
Height (mm)125 / 250125 / 250160
Drift loss* (%)≥ 0.0007 - 0.0005≥ 0.0007 - 0.0005≥ 0.0012 - 0.0006
Contin. operation temp. / Max. operation temp. (C°)70 / 80 (short time)55 / 60 (short time)70 / 80 (short time)
Max. face velocity (m/s)4.54.54.0
Drag coefficient2.22.22.6
Pitch (mm)181833 / 38
Max. distance between supports (mm)100010001200

 

Technical Data

* Based on the CTI ATC-140 test method (Drift Test Code) and EUROVENT standard OM-14-2009. These limits are guidelines only. The performance of the drift eliminators is indicated by the ratio drift loss/water flow rate. The efficiency of droplet separation depends on constant air velocity and an absolutely tight assembly of drift eliminator elements.