2H TUBEDEK® LAMELLA CLARIFIERS (TUBE SETTLERS)

COST SAVINGS BY SMALLER TANKS

TUBEdek® Lamella Clarifiers, also called tube settlers, are used for solids removal (sedimentation processes) in water and sewage treatment. TUBEdek® can be used in rectangular and in circular tanks.

  • TUBEdek FS41.50-2

    TUBEdek® FS41.50-2

  • TUBEdek FS41.50-2

    TUBEdek® FS41.50-2

  • TUBEdek FS41.84

    TUBEdek® FS41.84

  • TUBEdek KLP638

    TUBEdek® KLP638

Sludge, sand and silts in surface water, chemical precipitation and flocculation form solids which have to be removed. The most economic process to remove this pollution is parallel plate sedimentation.

TUBEdek® lamella clarifiers base on this physical principle. They consist of single profiles, which are assembled to a module forming several adjacent tubes and multiple sedimentation planes. This design increases the sedimentation area by a factor of 6 to 15 per square meter footprint. Using TUBEdek® tube settlers therefore decreases costs by being able to build smaller tanks.

Flexibility for all different applications

Our different tube settler types enable optimized sewage treatment processes. By choosing different tube lengths and heights and by varying the inclination angle, TUBEdek® settlers can be adjusted to all kinds of process requirements and tank geometry.

Engineering support

Please use our long experience and application know-how and ask for support in designing your clarifier or sedimentation tank.

FS 41.84FS 41.62FS 41.50 / FS 42.50KLP 638
Potable and process water---Highly loaded surface waterSurface water Groundwater Filter backwash waterLow solids load polishing
Waste waterPrimary sedi-mentation Activated sludge with low sludge volumeStormwater Humus tanks behind fixed film processesAquaculture Humus tanks behind fixed film processes Flocculated water StormwaterAqua-culture Polishing

 

 

 

 

FS 41.84FS41.62FS 41.50FS 42.50KLP 638
MaterialPVC
PPTV
PPTVPVC
PPTV
PPTVPPTV
Sedimentation area / Slope 60° (m²/m³)6.258111215
Sedimentation area / Slope 55°(m²/m³)791313.5-
Vertical module height (H/mm)700-2000On request500-2000500-1000610
Standard module height (H/mm)1000/ 1500100010001000610
Lamella pitch (mm)83 (+/-1)64 (+/-1)45 (+/-1)43 (+/-1)33 (average)
Hydraulic radius (cm)2.62.51.71.61.7
Contin. operation temp.

Max operation temp. PVC (°C)
55

60 (short term)
-55

60 (short term)
--
Contin. operation temp.

Max operation temp. PPTV (°C)
70

80 (short term)
70

80 (short term)
70

80 (short term)
70

80 (short term)
70

80 (short term)